Minimum Order Quantity | 1 Piece |
---|---|
Brand | Systronics |
Application | Industrial Use, Laboratory Use |
Wavelength Range | 340 to 1100 nm |
Model | 168 |
Baseline Flatness | Within +/-0.005 Abs (excluding noises) |
Detector | Si-Photodiode |
Photometric Range | -0.04 to 3.0 Abs |
Printer Port | Epson compatible Dot Matrix printer |
Stray Light | Less than 0.1%T at 340 nm |
Wavelength Accuracy | +/-1.0 nm |
Wavelength Repeatability | +/-0.5 nm |
Sample Holder | Automatic selection for Four cuvette (10 mm Pathlength) |
Source | Tungsten-Halogen lamp |
Automatic | Wavelength calibration |
Calibrations | LCD contrast adjustment |
Optimisations | System check at power On |
Optics | Single beam Czerny-Turner Monochromator with grating of 1200 line / mm |
Wavelength Resolution | 0.1 nm |
Wavelength Bandwidth | 2.0 nm |
Photometric Accuracy | +/-0.005 Abs at 1.0 Abs |
Photometric Repeatability | +/-0.002 Abs at 1.0 Abs |
Scan Speed | Slow, Medium, Fast |
Data Bank | For each operating mode ten users defined method can be storage using memory backup |
Accessories | Two matched 10 mm pathlength glass cuvettes |
Optional Accessories:
Data Interval:
Depends on wavelength scan range and scan speed, Minimum possible 0.1 nm for slow, 0.2 mn for medium and 0.4 nm for fast scan speeds.
Order Cut Off Filter:
Four glass filters, automatically FILTER positioned to eliminate grating spectral order interferences
Measuring modes:
Operating Modes:
Data Processing:
Data Storage:
For each operating mode, five users defined files can be stored using memory backup. For each mode one default file which stores last readings taken
RS-232 PORT
- Holders for 50 mm rectangular cuvettes Factory Installed
- Epson compatible Dot Matrix printer
- Windows-based interface
- Permanent data storage on hard disk
- Peak Pick/ Point Pick/ Valley Pick
- Expansion of spectra
- 1st, 2nd, 3rd and 4th Derivative
- Averaging of scans
- Subtraction of two scans
- Ratio, Corrected ratio, 2 point to Point net Abs
- Comparison of concentration
Data Interval:
Depends on wavelength scan range and scan speed, Minimum possible 0.1 nm for slow, 0.2 mn for medium and 0.4 nm for fast scan speeds.
Order Cut Off Filter:
Four glass filters, automatically FILTER positioned to eliminate grating spectral order interferences
Measuring modes:
- Absorbance
- %Transmittance
- Concentration (K factor, Multi-standard)
Operating Modes:
- Single Wavelength
- Multi-Wavelength
- Scan
- Time Scan
- Online measurement facility
Data Processing:
- Peak Pick / Valley Pick
- Zoom (Expansion) of Spectra
- Derivative
- Smoothening of spectra
Data Storage:
For each operating mode, five users defined files can be stored using memory backup. For each mode one default file which stores last readings taken
RS-232 PORT
- PC Link Data transfer
Data Presentation:
Display of graphic and tabular data on Graphics LCD (320* 240 pixels); a hard copy of graphic and data on printer.
Additional Information: