Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Microprocessor Flame Photometer 1385 And 1382

Microprocessor Flame Photometer 1385 And 1382

Product Details :

FEATURES

  • Microprocessor Based with Printer Interface
  • Auto Gas Cutoff (Model - 1385)
  • Auto Flame Failure Detection (Model - 1385)
  • Four Measurements in Single Aspiration
  • Setup Storage Facility
  • Sample Data Storage Facility
  • Curve Calibration Programmability Using Maximum of 5 Standards
  • Multiple Calibration Curve Saving Facility
  • Data Processing Through Curve Fitting Techniques, Least Square, Quadratic
  • Online Help Key
  • Direct Results in ppm and meq
  • Useful for Medical & Soil Testing

Microprocessor Flame Photometer - 1385 comes with flame failure detection and auto gas cutoff facility. In case of power failure, the gas cuts off automatically. In case the flame goes off accidently during work, the flame failure alarm sounds after few seconds

Microprocessor Flame Photometers - 1385 & 1382 are used for the determination of sodium, potassium, calcium and lithium. They uses the latest microcontroller technology and advanced engineering techniques so as to give enhanced and reproducibility. They have soft touch membrane key for ease of operations.

The sample solution is aspirated through an automiser. Sample, Air and the fuel are mixed in the mixing chamber which is then sprayed as a very fine mist into the flame. The color of the flame is changed depending upon the concentration of elements present. Radiations from the flame passes through the sensing system and specific narrow band interference filter which permits only the characteristic radiation to pass to the photo-detector. The output of the photo-detector is then processed by the microcontroller and the final results are displayed on the 20 x 4 line alphanumeric lcd with backlit.

In both models 5-Point calibration facility and non-linearity correction is provided through automatic curve fitting software. Facility has been provided for re-standardization with a single standard, thereby, eliminating the need of the multiple standards once a calibration has been performed.


SPECIFICATIONS

Mode

General

Serum

Urine

Range

Na: 0 - 100 ppm
Upto 250 meq/l, 1:100 dil

K: 0 - 100 ppm
Upto 250 meq/l, 1:100 dil

Ca: 0 - 100 ppm
Upto 250 meq/l, 1:100 dil

Li: 0 - 100 ppm
Upto 250 meq/l, 1:100 dil

Na: 0 - 200
1:100 dil

K: 0 - 10
1:100 dil

-


Li: 0 - 2
1:5 dil

Na: 0 - 250
1:100 dil

K: 0 - 100
1:100 dil

Ca: 0 - 10
1:2 dil

-

Sensitivity

General: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm

Filters

Na & K supplied (Ca & Li are optional at extra cost)

Resolution

0.1 ppm/meq

Reproducibility

< 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as maximum standard

Curve Fit Accuracy

< 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum stan

Write a review

Note: HTML is not translated!
    Bad           Good

Microprocessor Flame Photometer 1385 And 1382

  • ₹0

Seller information

  • Jayanti Scientific Instruments

  • Jayanti Scientific Instruments
  • New Delhi, India
  • Business Type :Manufacturer, Supplier
View profile
Please sign in to contact Jayanti Scientific Instruments

Tags: flame photometer