Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
TSP P-4000 Quartanary Gradient HPLC

TSP P-4000 Quartanary Gradient HPLC

Product Details :

Owing to our rich industry experience in this domain, we are indulged in offering a premium quality TSP P-4000 Quaternary Gradient HPLC. We check this product on various parameters to ensure its enhanced quality and performance. Keeping in mind the actual needs of our clients, we offer this product in customized options as per their detailed specifications. Apart from this, clients can avail this product from us at competitive prices.


P4000 Pump Specifications:

  • Pump Design: Dual in-line piston, pulse less design. Micro-stepped motor control. Floating piston bayonet-mounted heads. Patented ceramic check valves.
  • Flow accuracy: ±0.5% at 1 ml/min with water, after liquid end calibration
  • Flow precision: <0.2% RSD
  • Flow Range: 0.01 to 10 ml/min standard. Settable in 0.01 ml/min increments.
  • Composition Repeatability: 0.2% RSD
  • Gradient Linearity: ±0.5% from 10-90% composition
  • Maximum Pressure: 6000 psi, 420 bar, 42MPa with standard heads
  • Wetted Surfaces: Stainless steel or PEEK, titanium, ceramic, sapphire, Teflon, Tefzel, and polyethylene
  • Pressure Pulsation: <2% amplitude; <1% typical at 1ml/min water or methanol at >500 psi
  • Delay Volume: <0.6ml
  • Compressibility Compensation: Automatic
  • Shut down File: Protected in non-volatile memory
  • Flow Stability Test: Pump flow diagnostic to verify proper pump performance
  • Diagnostics: Diagnostic tests to verify proper electrical and mechanical operation
  • Communications: Hard wire external events connector. Run and Stop remote inputs; Ready, Run, Timed Event and Analogue Pressure outputs. SCM400 degas communication port.
  • Ambient Environment: 10-40°C, 5-95% relative humidity, non condensing.
  • TSP UV 2000 Dual Wavelength Detector


UV 2000 Detector Specifications:

  • Wavelength Ranges: D2 lamp: 190 to 365 nm, W lamp: 366 to 800 nm
  • Lamp: D2 and W standard
  • Wavelength Accuracy: ± 1.0 nm
  • Wavelength Precision: <0.01 nm
  • Bandwidth: 6 nm
  • Range Selections: 3.0, 2.0, 1.0, 0.5, 0.2, 0.1, 0.05, 0.02, 0.01, 0.005, 0.002, 0.001, 0.0005 AUFS
  • Absorbance Range: 0.0005 to 3.0 AUFS
  • Absorance Linearity @ 254 nm: 3.0 AUFS
  • Analogue Outputs: Outputs 1 and 2: Range-selectable over entire absorbance range


Communications:

  • Remote Inputs: Run, Stop, and Zero
  • Remote Output: Ready
  • AS 3000 Auto sampler Specification
  • Vial Capacity: 120 vials; 105 vials with temperature controlled tray


Variable Volume:

  • Injection Precision: <0.5%RSD@10uL
  • Injection Volume: 0.1-100 uL injections standard up to 1500uL injections with larger loops and syringe.
  • Sample Carry over: Typically < 0.01% at 400 uL
  • Minimum Sample Volume: 1 uL can be injected from 10 uL
  • Needle Height: Programmable in 0.1 mm increments
  • Method Files: Protected in non-volatile memory
  • Remote Inputs: Pump Ready, Inject Hold
  • Outputs: Pump Stop, Auto sampler Ready, Gradient Start, Inject
  • 4 Timed Event Outputs: RS-232C
  • Ambient Environment: 10-40°C, 5-95% relative humidity, non-condensing.


Additional Information:

  • Item Code: 2003