Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer

Product Details : 

  • Gas Control: Software controlled quick gas conversion and safety protection device used to analyse airacetylene flame and nitrous oxide-acetylene flame
  • Spray Chamber Metal Glass Spray: Burner Corrosion resistant titanium burners available for both air/acetylene and nitrous-oxide/ acetylene
  • Safety System: Safety interlock mechanism that monitors the burner type, burner fitted, gas pressures. Flame on/off sensors; Power failure automatic shutdown. Liquid trap system, pressure relief plug and flame shield to protect from UV radiation
  • Czerny-Turner grating monochromator, Anti-corrosive plastic sprayed chamber
  • 10cm single slot all-titanium burner
  • Highly efficient metal sleeve glass nebulizer with sucking up rate: 6-7ml/min
  • R928 Photomultiplier detector with high sensitivity and wide spectral range
  • Hydride analysis through Hydride vapor generator
  • Advance and reliable electronic design
  • Adopting large-scale programmable logic array and Inter I2C bus technology
  • European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system
  • Sequential measurement for multi-element determination in one sample
  • Auto-correction of sensitivity
  • Easy to use AAS analysis software under Windows operating system, Microprocessor with auto-control and data processing function
  • Less automated reasonable design provides economical usage
  • Digital LEC display, 2-lamp turret
  • Manual adjustment for wavelength and slit
  • Manual adjustment of vertical, horizontal positions and the rotation angle of the burner
  • Automatic adjustment of light source power
  • Auto-balance between light energy and negative high-voltage
  • Automatic calculation of mean, standard deviation and relative standard deviation in the range of 1-99
  • Automatic curve fitting with 3-7 standards
  • Auto-correction of sensitivity
  • Self-check function to check the current status of the instrument

SPECIFICATION

Wavelength Range
190-900 nm
Wavelength Accuracy
±0.5 nm
Spectral Bandwidth
0.1, 0.2, 0.4, 1.2 nm
Resolution
Less than 30%
Baseline Stability
0.005A/30min
Flame Temperature
None
Grating
1800 lines/mm
Focal Length
277 mm
Blazed Wavelength
250 nm
Concentration and Detection Limit
Cu: Characteristic concentration≤0.025mg/L Detection limit≤0.006mg/L
Graphite Furnace Temp. Range
None
Graphite Furnace Heating Rate
None
Graphite Furnace Tube Dimensions
None
Graphite Furnace Character Mass
None
Graphite Furnace Precision
None
Graphite Furnace Overall Dimension
None
Autosampler Overall Dimension
None
Graphite Furnace Weight (Net/Gross)
None
Autosampler Weight (Net/Gross)
None
Overall Dimension
1020x490x540 mm
Weight
80 kg
Catalog No.
9523129442


APPLICATION

Labocon Atomic Absorption Spectrophotometer LAAS 200 series is widely used in analytical chemistry protocols, applications such as food and drug safety, clinical diagnostics, petrochemical, agricultural, environmental monitoring.

Additional Information:

  • Item Code: LAAS-201