Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Autoranging Conductivity Meter

Autoranging Conductivity Meter

Product Details :

Product Code : HI-2300

HI 2300 measures EC, TDS, NaCl and temperature. In conductivity and TDS ranges (up to 500 mS/cm and 400 g/L respectively) the instrument automatically chooses the best scale to maintain the highest accuracy. EC calibration is a one-point procedure. Selectable calibration points are 0.00 µS, 84.0 µS, 1413 µS, 5.00 mS, 12.88 mS, 80.0 mS, and 111.8 mS selected according with the expected measurement range. NaCl calibration is a one-point procedure at 100.0% NaCl. Use HI 7037L calibration solution as a 100% NaCl standard solution. This instrument utilizes a four ring potentiometric probe with platinum sensors to offer versatility over typical amperometric designs. By utilizing the four ring method, it is possible to measure very low or high conductivity levels without changing probes. Three options of compensating for temperature are available for this instrument. The EC probe has a built-in temperature sensor which is used to automatically compensate the EC/TDS reading (from -9.9°C to 120.0°C), using the selected reference temperature (20 or 25ºC) and temperature compensation coefficient from (0.0 to 6.0%)/ºC. Manual (MTC): The temperature value, shown on the secondary LCD, can be manually set with the ARROW keys. The compensation is referenced at the selected temperature. All the other parameters of temperature compensation are settable similar to ATC. No Compensation (NoTC): For actual conductivity or TDS measurement, the temperature value shown on the secondary LCD is not taken into account. Cell constant is selectable between 0.5 and 1.700. TDS factor is selectable between 0.40 and 0.80. The HI 2300 also provides users with GLP capabilities. Good Laboratory Practice (GLP) is a set of functions that allows storage and retrieval of data regarding the status of the system. After a successful calibration, the meter automatically stores the date and time of calibration, the calibration solution used and the resulting cell constant value. All this information can be later recalled by the user. Other features include a lock range function and stability indicator. For PC communication, use the optional HI 92000 software and HI 920013 USB cable. The software is provided with an exclusive online guide of all the commands available and allows data printing, plotting and exporting. Product Details: Autoranging; The EC and TDS scales are autoranging. The meter automatically sets the scale with the highest possible resolution. Manual range selection and range lock Four ring potentiometric conductivity probe with internal temperature sensor Automatic (ATC), manual (MTC) or no temperature compensation (NoTC) GLP features Log-on-demand up to 500 records PC compatible via USB

Write a review

Note: HTML is not translated!
    Bad           Good

Autoranging Conductivity Meter

  • ₹0

Seller information

  • HANNA EQUIPMENTS INDIA PVT LTD

  • HANNA EQUIPMENTS INDIA PVT LTD
  • Navi Mumbai, India
  • Business Type :Supplier, Manufacturer
View profile
Please sign in to contact HANNA EQUIPMENTS INDIA PVT LTD

Tags: Conductivity Meter