Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Drop Point Apparatus
Drop Point Apparatus By Ring & Ball Method 
Test Method:

Dropping point determinations are used for identification and quality control purposes, and can be an indication of the highest temperature of utility for some applications. The sample is heated at a prescribed rate in a precision machined cup whose sides slope toward an opening at its center. The temperature at which a liquid drop first falls from the cup is the dropping point of the sample.
Features & benefits
Benefits
 Conforms to ASTM D566, D4950; NF T 60-102 and related specifications
Accesssories:
  •  TEMP. RISE : SETABLE FROM RANGE 0.1DEG C TO 9.9 DEG C.
  •  METHOD OF DETECTING DROP POINT : MANUAL.
  •  MICROPROCESSOR BASED TEMPERATURE CONTROL UNIT WITH ALL NECESSARY INTERLOCK.
  •  YOU CAN SET 10 DEG PRIOR TO EXPECTED DROP POINT. ONCE IT WILL REACH THERE IT WILL GIVE YOU AUDIO VISUAL ALARM AND WILL MAINTAIN THAT TEMPERATURE UNTIL YOU PRESS A RESET BUTTON.( UPTO THIS TIME YOU DON’T HAVE TO ATTEND THE EQUIPMENT.)
  •  AFTER REACHING PRESET TEMPERATURE, YOU HAVE TO SET RAMP RATE OF TEMPERATURE RISE RANGE FROM 0.1 DEG C TO 9.9 DEG C PER MINUTE. AFTER SETTING THE RAMP RATE, YOU HAVE TO PRESS THE START BUTTON.
  •  NOW, WHEN YOU DETECT DROP POINT, PRESS HOLD BUTTON THE TEMPERATURE DISPLAY WILL HOLD UNTIL YOU PRESS RESET BUTTON. THE HOLD DISPLAY OF TEMPERATURE INDICATE YOUR DROP POINT.
  •  HEATING LOAD: 800 WATT.
  •  POWER SUPPLY: 230V AC, 50 HZ, 10 AMP.
  •  STIRRER: MOTORISED.
  •  ILLUMINATION: BRIGHT LED TYPE.

 SAFETY FEATURES:

  • OVER TEMPERATURE PROTECTION.
  • OVER LOAD PROTECTION.
  • SHORT CIRCUIT PROTECTION.
  • INPUT POWER FLUCTUATION PROTECTION.
  • Maximum Temperature:
  • 550°F (288°C)

Bath Medium:
A high temperature heat transfer fluid having a flash point in excess of 400°C is recommended. Silicone fluid (P/N 355-001-002) is suitable.
Electrical Connection :
230V 50/60Hz, Single Phase, 6.5A
Included Accessories :

  •  Grease Cup, chromium plated brass
  •  Test Tube with indentations
  •  Cork Ring Guide
  •  Thermometer Corks (2)

 Polished Metal Rod.
Dimensions in inches :
 6” X6” X31”
 Nett Weight : 6.5 Kg
Shipping Information :
 Shipping Weight : 8.5 Kg
 Dimensions : 2.8 cu ft
Ordering Information:

CATALOGUE NO
PRODUCT DESCRIPTION
ELECTRICAL REQUIREMENT
HAMCO 54B
SEMIAUTOMATIC DROP POINT OF GREASE TEST APPARATUS
220-240V, 50/60Hz, 10.8 AMP
HAMCO 54B EXP
SEMIAUTOMATIC DROP POINT OF GREASE TEST APPARATUS
115V, 50/60Hz,20.8 AMP