Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Blood Gas And Electrolyte Analyzers
Blood Gas And Electrolyte Analyzers

The OPTI CCA-TS2 Blood Gas and Electrolyte Analyzer is an upgradable, portable ABG analyzer which uses a unique Optical Fluorescence Technology for accurate results. It also has a built-in thermal printer.
The OPTI CCA/CCA-TS Blood Gas and Electrolyte Analyzers are microprocessor-based instruments that measure optical fluorescence from discreet sensors called optical electrodes (optodes). A disposable, single-use cassette contains all of the elements needed for calibration, sample measurement and waste containment. Specific calibration information from the cassette is read into the analyzer by swiping the cassette package through the bar-code reader. The cassette is then placed into the measurement chamber.
The analyzer warms the cassette to 37.0°C (±0.1°C)/98.6°F (±0.1°F), and it performs a calibration verification on the sensors for PCO2 and PO2 by passing a precision calibration gas mixture across the optode sensors. The pH and electrolyte channels are calibrated with precision buffer solution contained in the cassette. When calibration is verified, the analyzer aspirates the blood sample into the cassette and across the optode sensors. After equilibrating with the blood sample, fluorescence emission is then measured.
Other details:
  • Sample Volume: 125 µL (60µL for B60 cassette)
  • Calibration Time: <90 seconds
  • Measurement Time: <120 seconds
  • Typical Cycle Time: <210 seconds
  • Operating Temperature: 10–32°C (50–90°F)
  • Sample Type: Whole blood, serum or plasma
  • Measurement Principle: Optical fluorescence, reflectance
  • Sample Application: Syringe, capillary or Comfort Sampler®
  • Data Storage: 200 patient records, 70 QC samples per level, 105 SRC samples per level, 300 user IDs and passwords
  • Voltage/Frequency: 120 or 240 AC, 50–60 Hz
  • Power Consumption (max.): 110 VA
  • Interface: Serial, Ethernet
  • Approvals: CE, UL and IVDD

Additional Information:

  • Item Code: 03
  • Production Capacity: 60
  • Delivery Time: Within 07 Days
  • Packaging Details: Machine with standard accessories