Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Cloud & Pour Point Bath (Cooling)
Product Details:
  • The unit is designed to meet the test method of ASTM D-2500-88/D-97.
  • For use to carry test of any petroleum oil as per test method.
  • The bath is triple walled in construction with inner chamber made of SS 304 & Exterior of G.I sheet duly finished in Powder coated shade.
  • The unit have 4 Compartment for 4 different temperature range in (STANDARD UNIT)
  • 1st compartment : (-) 01oC to (-) 02oC
  • 2nd compartment : (-) 15oC to (-) 18oC
  • 3rd compartment : (-) 32oC to (-) 34oC
  • 4th compartment : (-) 47oC to (-) 51oC
  • The top surface of units is of bakelite thick sheet for easy cleaning
  • Each compartment having 4 test jacket made of copper cylindrical flat bottom - 45 mm dia x 115 mm HT.
  • Test jar made of clear cylindrical glass flat bottom 30 to 33.5 mm dia x 115 to 125 mm height
  • All 4 compartment having 4 cooling system which includes hermetically sealed compressor, condenser, fan motor etc CFC free Cooling system.
  • All 4 Compartment Temperature are being controlled by separate Microprocessor based PID temperature controller with Digital indication
  • Selection of single, two or three chamber also.
CAT NO.
CHAMBER SIZE(W X L X HT.)
AVAILABLE COMPARMENT / CHAMBER(UNIT-TYPE)
TEST JACKET IN EACH CHAMBER
TEMP. RANGE
CIC - 103 A
7" x 14" x 6"
4 Chamber Compact
4 Nos. x 4
-1oC to -2oC, -15oC to -18oC,
-32oC to -34oC, -47oC to -51oC
CIC - 103 B
7" x 14" x 6"
4 Chamber Standard
4 Nos. x 4
-1oC to -2oC, -15oC to -18oC,
-47oC to -51oC
CIC - 103 C
7" x 14" x 6"
2 Chamber Medium
4 Nos. x 2
-1oC to -2oC, -15oC to -18oC
CIC - 103 D
7" x 14" x 6"
1 Chamber Economy
4 Nos. x 1
-32oC to -34oC


-700oC temp range available. Prices on request.

Optional

  • SAFETY CONTROLLER required to take over control in case of Temp. overshoot or if main PID Temp. Controller fails.
  • PRINTER OUTPUT facility required to record PV, SV, Actual Date/Time with variable print time interval, 5000 line memory & Audio alarm facility in case of memory full.
  • AUDIO ALARM facility to alert for Temp. Overshoot/undershoot.
  • TIMER facility.
  • 21 CFR PART 11 COMPLIANCE SOFTWARE for Data Management.