Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
General Purpose Centrifuge

General Purpose Centrifuge

 The Centrifuge should have a feature to install and remove rotor without tool in less than 5 seconds with just a push of a button for quick and easy change of rotors for different applications  The centrifuge must be able to display both air/chamber temperature as well as temperature in the sample.(for refrigerated versions)  Dual Timer mode- At Start and at Speed  The centrifuge must have an option for automatic lid opening at the end of the run.  The centrifuge must have capability of password protection for the programs.  The centrifuge must have capability of password protection for lid opening.  The centrifuge must be capable for maintaining temperatures of -10 deg to 40deg  The centrifuge must be able to display set parameters together with actual values, and parameters must be readable at a distance of at least 5 meters.  The centrifuge must have a minimum of 5 “direct recall” program keys, and capability for up to 99 programs.  The centrifuge must be CE, CSA and UL certified for safety containment.. ISO 13485 international standard.  The angle rotors must be manufactured from a highly corrosion and fatigue resistant material. The Fixed Angle Non corrosive light weight rotors should be warranted for at least12 to 15 years  The bucket lids for Swing out rotors must operate in a safe manner without spring clips or metal components. The buckets and rotor sealing lids must be certified for biocontainment by a 3rd party lab of worldwide recognition.  The centrifuge must be capable of running up to 4 x 400 ml bottles in swing-out configuration and in certified sealed conditions.  The centrifuge must be capable of running Fixed Angle light weight non corrosive Rotor of 6 x 100 ml tubes at speeds of at least 24500 xg. To spin 50/15 ml conical and round tubes. The rotor should be warranted for 12 to 15 years.  The centrifuge must be capable of running a minimum of 14 x 50 ml disposable conical tubes at speeds of at least 12000 xg.in a fixed angle non corrosive light weight rotor  The centrifuge must be capable of running at least 8 x 50 ml disposable conical tubes in individually sealed vessels in a fixed angle rotor at 7100xg, certified for biocontainment. Rotors REQUIRED  FIXED ANGLE ROTOR WITH 6*100ML CAPACITY AND ABOVE 24000 G FORCE ,ALONG WITH 50ml AND 15ML ADAPTER.  FIXED ANGLE ROTOR WITH 48*2ML CAPACITY WITH ABOVE 25000 G FORCE

Write a review

Note: HTML is not translated!
    Bad           Good

General Purpose Centrifuge

  • ₹0

Seller information

View profile
Please sign in to contact Scientific Enterprises

Tags: General Purpose Centrifuge