Click Image for Gallery
PD 450
Product Features :
- Optical RDO technology reduces maintenance time and costs
- Maintenance free optical probe with no electrolyte eliminates hassle of replacing delicate membranes and salt build up from refilling solutions
- Switch between pH, mV, % saturation and mg/L (ppm) dissolved oxygen – With the press of a button
- Durable waterproof and dustproof design with IP67 rating
- Large, backlit graphic display provides measurement with temperature
- Calibrate up to 5 points automatically with USA or NIST buffer groups (up to 6 points with DIN). New manual option allows calibration with up to 5 custom buffer standards
- Auto buffer recognition – Automatically identifies the correct pH buffer for rapid calibration
- Calibration due alarm – Set a visible reminder when it is time to recalibrate the meter
- Ready indicator, manual or automatic measurement hold feature and optional automatic shutoff function
- Store up to 500 data sets – Easy USB or RS232 output with optional data cables
- Built-in real-time clock stamps stored data and calibration data with time and date – Meets standards for GLP (Good Laboratory Practices)
Product Description :
| Product Specification | Description |
| pH Range | -2.00 to 16.00 pH |
| Resolution / Accuracy | 0.01 pH / ±0.01 pH |
| Calibration | Up to 6 points (USA,NIST,DIN or Custom) |
| mV Range | ±2000 mV |
| Resolution / Accuracy | 0.1 mV ±999.9 mV; 1 mV beyond / ± 0.2 mV ±2 LSD or ±0.5 % of reading; whichever is greater |
| Calibration | ±200 mV |
| Dissolved Oxygen Range | 0 to 200 %; 0 to 20 ppm / mg / L |
| Resolution / Accuracy | 0.10 %; 0.1 ppm / mg / L / ±2 %; ±0.1 ppm or mg/L up to 8; ± 0.2 ppm or mg/L above 8 |
| Calibration | Zero and saturation |
| Temperature Range | -10.0 to 110.0 ºC (14.0 to 230.0 ºF) |
| Resolution / Accuracy | 0.1 0C/ 0F / ± 0.5 ºC; ± 0.9 ºF |
| Calibration | Offset in 0.1 increments, ±10 ºC or ±18 ºF |
| Display | Custom LCD with backlight |
| Memory | Stores up to 500 data sets |
| Output | USB or RS232 |
| Real-Time Clock | Time and date stamp on Calibration and stored data |
| Temperature Compensation | Automatic or manual from -10 to 110 ºC |
| Pressure & Salinity Compensation | Manual |
| Power | Two AA batteries (included), >100 hours (without backlight); AC adapter (optional) |
| Standard supply | Meter, pH electrode, RDO electrode with sensor cap, two AA batteries, hard carry case, USB cable, RDO stainless steel weight/guard, RDO calibration chamber |
| Dimensions (L x W x H) | Meter 77/8” x 31/8” x 21/4” (20 x 8.3 x 5.7 cm) Boxed 91/8” x 91/8” x 23/4” (23 x 23 x 7 cm) |
| Weight | Meter 1 lb (0.5 kg) Boxed 1.4 lb (0.7 kg) |