Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Protein Nitrogen Estimation KT 8400

Protein Nitrogen Estimation KT 8400

Reagent pump volumes: 0 – 150 ml in steps of 10 ml Delay: 0 – 1800 seconds Steam addition for equillibrium: 0 – 15 seconds Water consumption (during distillation only): 2 l/min at water temp of 30°C,1 l/min at water temp of 15°C Corrosion free coloured plastic cabinet. Cooling water flow control Distillate temperature monitoring and warning facility. Polypropylene splash head Polypropylene tube emptying vessel Bellow pumps for reagent addition . 20L reagent tanks fitted with proper capping and reagent sensors. Reagent sensors for Water/Alkali/Waste/titrant Automatic alkali addition/ dilution water addition /receiver solution addition and calculation of result.Inbuilt titration vessel . Automatic cleaning of titration vessel Maintenance free titration device. Must be connected to LAN network for remote monitoring and connection to LIMS. Automatic opening and closing of distillation safety door. Glass condenser with insulation and visible at both ends and no joints and free of metal. Autosampler for 20 place should be quoted in optional.Autosampler should not need shifting of tubes from digestion system to autosampler one by one instead entire digestion rack should be able to go into the autosampler to save time and avoid risk of breakage and spillage of chemicals. Automatic Block digestor with autolift (as per below specification ) with all the accessories and catalyst tablets. Number of samples: 20 Temperature range : 100 to 440 degree C Temperature setting repeatability : 1 degree C Temperature readout : digital Over temperature protection Time setting per step : 1 - 1199 min Scrubber to neutralise fumes: It should not need running tap water during digestion. It should have inbuilt pump .It should have Glass bottle for reagents. It should have trap between pump and scrubbing area to avoid fumes. To be supplied with ,Cyclone Grinding mill for sample preparation with 0.5 mm and 1 mm sample size . IMPORTANT NOTE : All quoted items must be from the same manufacturer . 

Write a review

Note: HTML is not translated!
    Bad           Good

Protein Nitrogen Estimation KT 8400

  • ₹0

Seller information

View profile
Please sign in to contact Scientific Enterprises

Tags: Protein Nitrogen Estimation KT 8400