Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Atomic Abortion Spectrophotometer

Atomic Abortion Spectrophotometer

Product Details :

Aiming to satisfy our clients, we are engaged in offering a quality approved Atomic Abortion Spectrophotometer. In adherence to the international quality standards, our offered spectrophotometer is assembled using optimum grade components and sophisticated technology at vendor's end. The offered spectrophotometer is highly used in scientific laboratory for data processing and data interpretation from the database. Apart from this, our offered spectrophotometer can be availed in various configurations and models at industry leading prices.


Details:

ModelSpectrAA-220
Burner-AtomizerChangeable, laminar, adjustable, optional N2O, premix universal atomizer with fully adjustable nebulizer, fully shielded flame with double-skin chimney
Other Information (Staining Posts)2000
Format (Wavelenght, nm)1 channel, double beam - for more information please see comments.1 channel, double beam, time-shared, rotating-beam combiner
Power Needed100-120, 220/203/240
Hz (Operating)50/60
Background Correct (Detection Limits,ppb)Fast (2 msec) deuterium arc lamp to 2.3 absorbance units, 185-425 nm, electronic beam balance, with automatic attenuation.
Gas RegulatorsManual control with automatic gas changeover or Hammer instantaneous programmable control; interlocks on power, gas, burner present, burner type, flame, spray-chamber bung, flame shield, liquid trap; cutoff solenoids external to instrument case
IgnitionPush button, automatic flame off
MonoChromaotarCzerny-Turner with 1,200 lines/mm, holographic quartzovercoated grating, automatic wavelength & slit-size control
Focal length, mm (Dimensions (HXWXD), MAIN)250
Wavelength, nm (UV Radiation Intensity)185-900
Resolution, nm0.2, 0.5, 1; 0.5 reduced
Scattering,nm/mm3.2-2.4
Detection Limits,ppb
Ca (Detection Limits,ppb)0.4
Cu (Detection Limits,ppb)38749
Fe (Detection Limits,ppb)38783
Li (Testing Range, MMOL/L)0.9
Mg (Basic/Time, min)0.3
As (Detection Limits,ppb)0.22
Cu (Detection Limits,ppb)0.15
Ni (Detection Limits ,ppb)0.38
Pb (Detection Limits,ppb)0.1
Se (Detection Limits,ppb)0.23