Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Atomic Absorption Spectrophotometer
Atomic Absorption Spectrophotometer
Product Details:

Lasany presents a wide range of Quality Equipment required in day-to-day function of a Chemical Laboratory to Advanced Instruments used for Quality Assurance/Control and Research. Our Atomic Absorption Spectrophotometer offers a State-of-the-art technology bundled with many features as a complete economical package.

SALIENT FEATURES
  • Advance technology for intelligent stray light measure and correction
  • Original Optical Noise Reduction & Automatic measurement and stray light dynamic detected without any reference materials and incremental cost. It improves instrument’s optical performance, optical  precision, linear range and background correction effectively
  • Develop internal lamp control technology. It makes normal hallow cathode lamps self-absorption background correction possible without and influence to instrument's stability.
  • Meanwhile it will prolong working life of the lamps. Normal hallow cathode lamps are highly economical than special lamps
  • Original ''Hg lamp-regent'' gradient measurement. we established an exact mathematical model to estimate “single beam linear and balance "specification. This technology provided a fast and
  • economic method for instrument self testing system. It also established a brand new method to improve instrument's detection Performance.
  • Numerous technological innovation and renewal such as design aesthetics, element lamp multi dimensional automatic adjustment system, gas path electronics functional and modular design, No-adjustment D-lamp holder and so on.


OPTIONS:
Graphite Furnace
Auto-Sampler for Graphite Furnace
Hydride Generator
Wide range of Hollow-Cathode Lamps(Single/Multi Element)

Technical Specifications

Optical System
Instrument Type
Single Beam Reflection Achromatic Optics System
Monochromator
Aberration Corrected Czerny-Turner

Dispersion elements
Grating system 1200 line/mm characterization area 40mm2
Scintillation wavelength 250nm
Bandwidth
0.1,0.2,0.4,1nm(4 step auto switching)
WL Range
190-900
WL Accuracy
±0.2
WL Repeatability
±0.1 nm max
Resolution
Min 3 lines (279.5 & 279.8 peak and Valley )

HCL housing
Standard 4 lamp turret .
( 1 for measurement , 3 in warm-up mode ) Option :- 6 Lamp / 8 Lamp Turret .
Gas control
Automatic control & optimization (flow/pressure)

Safety measures
Gas Leak check, prevention of gas release when flame dies out,
prevention of flashback through pressure monitoring.

Photometric properties
Measurement
Aberration-corrected Czerny-Turner mounting
Photometric Range
0-125%, -0.1-3.00A
Static Baseline Drift
(Cu) +-0.003A/30min
Dynamic Baseline Drift
(Cu) +-0.006A/30min
Background Correction
High speed self-reversal (BGC-SR) method: High
speed D2 lamp method (BGC-D2)
Atomization System

Flame
Characteristic Concentration
(Cu) 0.025 μg/ml max
Detection limit
(Cu) 0.004 μg/ml max
Precision
RDS =0.5%
Burner
Air cooled Titanium
Nebulizer
High-efficient Nebulizer
Spray chamber
Anticorrosion material
Safety measures
Flame fuel gas, power assisted gas abnormal pressure protection

Data Process
Test Manner
Flame , flame emission .
Concentration
standard curve, standard addition, interpolation
Times of repetitive
Measurement 1-30 times, Average Value of A&C
Report Print
parameters, date result

Other
Dimension & Weight
(Flame)
700×420×550 mm; 103 kg(approx.)
Power (Main unit with(Flame)
AC 220 V ±10%, 50 Hz without sharp fluctuations.
Working Temperature range
10~300C

Working Humidity range
40%~85%