Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
KARL FISCHER VOLUMETRIC TITRATOR
Specification
  • Brand HANNA
  • MODEL HI903
  • RANGE 100 PPM TO 100%
Description
  • Titration Specifications  
  • Range 100 ppm to 100%
  • Resolution 1 ppm to 0.0001%
  • Result Units %, ppm, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg/pc, μg/pc
  • Sample Types liquid or solid
  • Pre-Titration Conditioning automatic
  • Background Drift Correction automatic or user-selectable value
  • Endpoint Criteria fixed mV persistence, relative drift stop or absolute drift stop
  • Dosing dynamic with optional pre-dispensing rate
  • Result Statistic mean, standard deviation
  • Dosing System Specifications  
  • Dosing Pump Resolution 1/40000 of the burette volume (0.125 μL per dose) with 5 mL burette
  • Dosing Pump Accuracy ±0.1% of full burette volume
  • Syringe 5 mL precision ground glass with PTFE plunger
  • Valve motor-driven 3-way, PTFE liquid contact material
  • Tubing PTFE with light block and thermal jacketing
  • Dispensing Tip glass, fixed position, anti-diffusing
  • Titration Vessel conical with operation volume between 50-150 mL
  • Solvent Handling System sealed system, integrated diaphragm air pump
Sensor System Specifications  
Sensor Type HI76320 dual platinum pin polarization electrode
Sensor Connection BNC
Polarization Current 1, 2, 5, 10, 15, 20, 30 or 40 μA
Voltage Range 2 mV to 1000 mV
Voltage Resolution 0.1 mV
Accuracy (@25ºC/77ºF) ±0.1%
Additional Specifications  
Programmable Stirrer magnetic, optically regulated, digital stirrer; 200 to 2000 rpm; resolution 100 rpm
Display 5.7” (320 x 240 pixel) color LCD
Methods up to 100 methods (standard and user-defined)
Logging Data up to 100 complete titration reports and drift rate reports can be stored
Peripherals (Rear) connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232
GLP Conformity Good Laboratory Practice and instrument data storage and printing
Languages English, Portuguese. Spanish, and French
Enclosure Material ABS plastic and steel
Keypad polycarbonate
Operating Environment 10 to 40°C (50 to 104°F), up to 95% RH
Storage Environment -20 to 70°C (-4 to 158°F), up to 95% RH
Power Supply 100-240 VAC; "-01" models, US plug (type A); "-02" models, European plug (type C)
Dimensions 390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in)