Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
RESEARCH POLARIMETER

Model:LJ-105

CONSTRUCTION:

Entire optical train is mounted on a rigid east aluminium support of elegant design and the sodium lamp on its spherical housing forms is an integral part of the instruments and is operated on Sodium Lamp of 35 watts 220 Volt AC. through chock.

WORKING INSTRUCTION:

The switch is to be plugged through chock, Start the working when sodium bulb become yellow. The left hand Micrometer drum knob has 0 to 20 divisions. First set the knob to 0. Then rotate the right hand knob & set 0 to single line inside the scale eyepiece. Then check the Moon shade by focussing the scale. Both the shade shall become equal. Fill the juice to pole tube and put it In polarimeter and close the cover. Then focus the moon shade difference from moon eyepiece. Rotate the right hand knob till the shade become equal. When they become equal check the reading.

SPECIFICATIONS :

Range of measurement

+130° to -30°

Vernier Accuracy

0.1° (I.S.S.)

Telescopic Magnification

4.5 X

Analyser

Glans Thompson Prisms.

Polariser and Half shade

Prism system

Polarlsing Aperture

6 mm.

Light Source

Sodium Lamp of 35 Watts

Filter

Suitable for use with Polarimeter Tubes up to 200 mm


Model:LJ-106

CONSTRUCTION:

The entire optical train is mounted on a rigid east aluminium support of elegant design and the sodium lamp on its spherical housing forms is an integral part of the instruments and is operated on Sodium Lamp of 35 watts 220 Volt AC. through chock. 

WORKING INSTRUCTION:

The switch is to be plugged through chock, Start the working when sodium bulb become yellow. The left hand Micrometer drum knob has 0 to 20 divisions. First set the knob to 0. Then rotate the right hand knob & set 0 to single line inside the scale eyepiece. Then check the Moon shade by focussing the scale. Both the shade shall become equal. Fill the juice to pole tube and put it In polarimeter and close the cover. Then focus the moon shade difference from moon eyepiece. Rotate the right hand knob till the shade become equal. When they become equal check the reading.

SPECIFICATIONS : 

Range of measurement

+130° to -30°

Vernier Accuracy

0.1° (I.S.S.)

Telescopic Magnification

4.5 X

Analyser

Glans Thompson Prisms.

Polariser and Half shade

Prism system

Polarlsing Aperture

6 mm.

Light Source

Sodium Lamp of 35 Watts

Filter

Suitable for use with Polarimeter Tubes up to 200 mm

 

 

 

 