Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
BioGas Analyser 3000

BioGas Analyser 3000

Gas Analyser

BioGas Analyser 3000


Product Features :

  •  CH4 CO2 & O2 - standard measurements
  •  H2S, H2 and CO - choice of up to two optional measurements
  •  Modular design enabling hot-swap for serviceability and onsite maintenance
  •  User calibration function to maintain accuracy & ensure data reliability in extreme temperatures
  •  ATEX and IECEx certified for use in potentially explosive gas atmospheres - zone 2
  •  ISO / IEC 17025 calibration for optimal accuracy
  •  Ability to monitor the gas control process before and after desulphurisation
  •  Continuous monitoring option
  •  Up to 4 sample points to monitor the complete gas control process
  •  IP65 rated for weather proofing
  •  Built in liquid level monitoring with a dedicated alarm to inform the user that the contents of the catchpot requires emptying or an optional automated moisture removal drain
  •  Gas alarms & fault notifications
  •  6 x 4-20mA outputs
  •  Modbus RTU communication
  •  Optional Profibus and Profinet communication
  •  Clear, visual and informative colour display
  •  Optional heater to extend operating temperature range to -20°C
  •  Extended Warranty & Service pack options through approved global service centres


Technical Specifications

  • GENERAL SPECIFICATION
  • Number of sampling points: 1-4
  • Gases to be monitored: CH4, CO2 and O2 with optional H2S, H2 and CO (choice of up to 5)
  • Reading intervals: User definable, with a continuous1 CH4, CO2 and O2 option available
  • Operating temperature range: 0°C to +50°C without heater, -20°C to +50°C with heater


POWER

  • Mains options: 110-230 VAC 50/60 Hz
  • Consumption: 155W max.
  • Backup memory: Lithium manganese dioxide backup battery for memory retention


GAS RANGES

  • Gases measured
  • CH4 and CO2: By dual wavelength infrared cell with reference channel
  • O2: By internal electrochemical cell
  • H2S / H2 / CO: By internal / external electrochemical cell
  • Cell
  • Range
  • Typical accuracy (range : accuracy)*
  • Standard gas cells
  • CH4
  • 0-100%
  • 0-70% : ±0.5% (vol)
  • 70-100% : ±1.5% (vol)
  • CO2
  • 0-100%
  • 0-60% : ±0.5% (vol)
  • 60-100% : ±1.5% (vol)
  • O2
  • 0-25%
  • 0-25% : ±1.0% (vol)
  • Cell
  • Range
  • Typical accuracy (range : accuracy)*
  • Internal accuracy
  • External accuracy
  • Optional gas cells
  • H2S
  • 0-50ppm
  • ±1.5% FS
  • ±1.5% FS
  • H2S
  • 0-200ppm
  • ±2.0% FS
  • ±1.5% FS
  • H2S
  • 0-500ppm
  • ±2.0% FS
  • ±2.0% FS
  • H2S
  • 0-1,000ppm
  • ±2.0% FS
  • ±2.0% FS
  • H2S
  • 0-5,000ppm
  • ±2.0% FS
  • ±100ppm or 5% of reading (if greater)
  • H2S
  • 0-10,000ppm
  • ±5.0% FS
  • ±200ppm or 5% of reading (if greater)
  • CO
  • 0-1,000ppm
  • ±2.0% FS
  • ±3.0% FS
  • H2
  • 0-1,000ppm
  • ±2.5% FS
  • ±1.5% FS
  • Range
  • Response time
  • Response time, T90**
  • CH4
  • ≤10 seconds
  • H2S (0-50ppm)
  • ≤30 seconds
  • CO2
  • ≤10 seconds
  • H2S (0-200ppm)
  • ≤35 seconds
  • O2
  • ≤20 seconds
  • H2S (0-500ppm)
  • ≤35 seconds
  • H2S (0-1,000ppm)
  • ≤35 seconds
  • H2
  • <90 seconds
  • H2S (0-5,000ppm)
  • ≤40 seconds
  • CO
  • <30 seconds
  • H2S (0-10,000ppm)
  • ≤40 seconds
  • ** Times are taken from the point gas enters the BIOGAS 3000 module. Sample times will vary depending on length of sample pipe
  • Cell lifetime
  • O2 cell is 3 years in air, all other cells 2 years in air             


PUMP

  • Flow: 300ml / min typically
  • Flow-fail point: Flow rate less than 75ml/min or vacuum greater than 350mbar
  • Maximum vacuum restart: -375 mbar


COMMUNICATIONS

Output channels:

  • Up to six analogue 4-20mA output channels that are user configurable for current sink or source inputs plus Modbus RTU digital output.
  • Optional Profibus module
  • Optional Profinet module


Alarm notifications: 

  • 1 x fault relay
  • 7 x user-configrable alarms that can trigger a relay when above or below a set value.
  • In addition, one can be used to indicate to the operator when the catchpot is full and requires emptying.


Relay outputs: 

  • Single pole changeover 6A 24Vdc relay volt free


ENVIRONMENT CONDITIONS

  • Operating pressures: -350 mbar to +350 mbar
  • IP rating: IP65
  • Humidity: 0-95% non-condensing humidity


PHYSICAL

Weight: 36.5kg

Size: 650 x 600 x 210mm (with supplied wall mounting brackets)

Enclosure: Stainless steel, 600 x 600 x 210mm, IP65 rated

Operation keys: Alpha-numeric keypad with ‘tactile’ membrane

Display: Ultra-clear high resolution 4.3” full colour TFT

Moisture removal filters: User replaceable microfibre filter and 2.0μm ptfe water traps

Heater option: Optional 100W mains powered ATEX certified heater for 110V or 230V mains supply


CERTIFICATION RATING

  • ISO17025: Calibrated under UKAS accreditation (certificate number 4533)
  • ATEX / IECEx marking: II 3G Ex nA nC IIA T1 Gc (-20°C ≤ Ta ≤ +50°C)
  • BS EN 61010-1:2010: Safety requirements for electrical equipment for measurement, control, and laboratory use
  • BS EN 50270:2006: Electromagnetic compatibility - electrical apparatus for the detection and measurement


Product Applications

  • Agricultural waste
  • Biogas upgrading
  • Landfill gas monitoring
  • Farm waste AD (small scale)
  • Gas flaring
  • Mixed food waste AD
  • Sewage/waste water treatment AD