Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Automatic Flash Point Apparatus
Automatic Flash Point Apparatus 
Test Method : lash Point is Lowest temperature at which application of the ignition source causes the vapour of a specimen of the sample to ignite under the specified condition of the test. The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.
Conforms to the specifications of : ASTM D92; IP 36; ISO 2592
Auto Fire Point Detection :
In addition to the automatic detection of flash point , fire point can be determined automatically too.The fire Point is detected when the ionisation ring detects 5 sec for continous burning.
Accessories Will Be Supplied With Equipment :
  •  Cooking Bulb — 5 No (Cat No Hamco31s1)
  •  Needle — 1 No (Cat No Hamco31s7)
  •  Syringe — 1 No (Cat No Hamco31s7)
  •  Cooking Bulb Filling Rack – 1 No. (Cat No Hamco31ac1)
  •  Ss Tong — 1 No. (Cat No Hamco31ac2)
  • Ceramic Board Plate – 1 No. (Cat No Hamco31s6)

Spares Required For 5 Year Trouble Free Operation :

  •  Cooking Bulb — 200 Nos.(Cat No Hamco31s1)
  •  Temperature Controller — 1 No.(Cat No Hamco31s2)
  •  Solid State Relay — 3 No.(Cat No Hamco31s3)
  •  Switchgear(Mainswitch & Bulb ) – 3 No Each (Cat No Hamco31s4)
  •  Ceramic Split Bend Heater – 2 No. (Cat No Hamco31s5)
  •  Ceramic Board Plate – 1 No.(Cat No Hamco31s6)
  •  Sample Filler Needle & Syringe ( Cat No Hamco31s7)

Electrical Requirement :

  •  220-240V, 50/60Hz, Single Phase, 10.9A
  • 5OR 115V, 50/60Hz, Single Phase, 20.8A
  • Dimension : Ixwxh,in.(cm)
  •  16”x21.5”x14.5” (41x55x37)
  •  Net Weight: 64 lbs (29kg)

Shipping Information :

  •  Shipping Weight: 78 lbs (35kg)
  • Dimensions: 8.2 Cu. ft.

Automatically Shut The Machine And Horn The Buzzer In The Case :

  •  EFP+30oC or at 400oC is reached
  •  Temperature sensor is found defective
  •  Flash detector is found defective
  •  Arm is not set in place
  •  Cup is not set in place
  •  Heater has gone
  •  Side Ignition coil/solenoid has gone

Installation Site :

  • Temperature : 0 to 45 degree C. , Humidity : Less Than 90% ( No condensation).
    Utility :
  •  Power Supply 230 V Ac, 16 amp.
  •  GAS Supply ( LP Gas or Natural Gas Pressure Less than 9.8 Kpa)
    Ordering Information:
CATALOGUE NO
PRODUCT DESCRIPTION
ELECTRICAL REQUIREMENT
HAMCO 19D
AUTOMATIC FLASH POINT APPARATUS
220-240V, 50/60Hz
HAMCO 19D EXP
AUTOMATIC FLASH POINT APPARATUS
115V, 50/60Hz
HAMCO 19S1
CERAMIC HEATER
HAMCO 19S2
THERMAL INSULATOR
HAMCO 19AC1
COC CUP
HAMCO 19S3
SIDE IGNITOR WITH COIL
HAMCO 19S4
COOLING FAN
HAMCO 19AC8
THERMAL PRINTER ROLL