Click Image for Gallery
Oxidation Stability Tester:
OBA-1
- Semi-automatic oxidation stability tester for gasoline and aviation fuel
- Digital PA 5-OBA programmable manometers and 4 test places for parallel testing
- Available with liquid bath or dry-heat bath
The semi-automatic OBA 1 is used to determine the oxidation stability (induction period) and the tendency to form gum (potential residue) under accelerated oxidation conditions.
OBA 1 is suitable for oxidation stability applications of gasoline and aviation fuel.
Key Features
Benefits at a Glance
- Digital PA 5-OBA programmable manometers
- Pressure-certified oxidation vessels
- 4 test places for parallel testing
- PC-software for data handling
Convenient Operation
- The PA 5-OBA is a programmable manometer with a digital display and pressure connection. It determines automatically the induction period and checks the leakage stability of the oxidation vessel before starting the test automatically.
- Data can be transferred from the manometer to your PC via an USB interface (cable included)
- The included PC-software PetroNet Standard allows to monitor the numerical and graphical data on the screen.
- Convenient temperature reading with Pt1000 temperature sensor (optional) and correction of the induction period according to the used method
Customized User Flexibility
- Available with liquid bath or dry-heat bath
- Dongle to unlock the PA 5 Professional module of the PetroNet Standard software to allow full access to the programmable parameters of the PA 5 manometers (optional)
- PA 5 manometer pressure calibrator (optional)
- Dry-heat bath calibration set (optional)
- Certified manometers available with manufacturer's calibration certificate or official (DKD) calibration certificate (optional)
- Tool set to ease the pressure vessel opening and closing procedure (optional)
- Support shelf for test vessel (optional)
Technical specifications :
Application range | up to 200 °C (OBA 1) up to 120 °C (OBA 1/T) |
---|---|
Tempering | Liquid bath, 45 L (OBA 1) Dry-heat bath (OBA 1/T) |
Test places | 4 |
Pressure range measurement | 0 bar to 14 bar or 1400 kPa or 203 psi |
Resolution displayed | 1 mbar / 0.1 °C |
Internal memory | 57,000 data sets |
Oxidation vessel | Stainless steel, certified for 40 bar, static pressure at 100 °C |
Interface | USB |
Power supply | 115 V, 50 Hz/60 Hz, 1000 W or 230 V, 50 Hz/60 Hz, 2000 W (OBA 1) 115 V, 50 Hz/60 Hz, 900 W or 230 V, 50 Hz/60 Hz, 2300 W (OBA 1/T) |
Dimensions (W x D x H) | 430 mm x 430 mm x 900 mm (OBA 1) 900 mm x 600 mm x 900 mm (OBA 1/T) |
Weight | 31 kg (OBA 1) 66 kg (OBA 1/T) |
Resolution | 0.1 kPa |