Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.
Sugar Analyzing System

Sugar Analyzing System:

Sucrolyser

  • Analysis of sugar content, dry substance, and apparent purity
  • Complies with the official ICUMSA methods as well as other standards (e.g. OIML and Australian standard K157)
  • Fast measurements of up to 120 measurements/hour due to temperature-compensated analysis of %Brix and °Z

Sucrolyser is a powerful sugar analysis system for sugar factories. It is used in the quality control of sugar cane as a part of payment analysis or as an extended laboratory system for multiple methods of sample preparation and chemical factory control. Independent of the clarifying agent, all kinds of samples can be checked on their sugar content. As a combined arrangement of an MCP Sucromat and an Abbemat refractometer, the Sucrolyser system offers advanced possibilities additional to each of these instruments’ individual features.


Key Features

Automatic and efficient purity analysis of sugar products

The combination of Anton Paar’s MCP Sucromat sugar polarimeter and Abbemat refractometer creates a powerful sugar analysis system, substantially increasing the performance of your sugar factory. The raw, intermediate, and final products of sugar manufacturing can be checked on sugar content (Pol, °Z), dry substance (°Brix), and apparent purity (%) – all in one cycle – density-corrected according to the Schmitz table.


Full compliance to ICUMSA

The Sucrolyser system complies with the official ICUMSA methods as well as further national and international standards (e.g. OIML and Australian standard K157). Established methods with and without temperature correction (depending on application) for sugar content measurement are integrated as default. Additionally, for temperature-controlled measurements, Anton Paar offers Peltier temperature control to provide homogeneous and fast temperature equilibrium. The Sucrolyser system covers all requirements in the reception lab for the analysis of sugar cane juice and in quality control for diverse analysis tasks.


2 instruments – 1 interface: fast measurements with high flexibility

Handling the Sucrolyser sugar analyzer is clear and easy: When connected, both instruments can be operated through the MCP Sucromat’s big touchscreen and all data is recorded in one report. Samples such as sugar cane juice can be measured by simply pouring them into a filling funnel, which enables a smooth workflow and high throughput. In case you want to perform sugar content measurements with samples which were clarified lead-free and which are hence darker than samples clarified with lead, MCP Sucromat models can be equipped with the second official ICUMSA wavelength of 880 nm – upgraded on-site or already purchased as dual-wavelength saccharimeters.


Sturdy setup for reliable results and a long instrument life

Neither humidity nor temperature nor vibrations will influence sugar content measurements performed with the robust Sucrolyser system as sensitive optical and electronic components are located in a sealed housing, resistant to dust and spillage. To ensure durability, there are no moving parts inside of the instruments. Long-life LED light sources, which are maintenance-free for 100,000 hours, reduce downtimes of the instruments to the bare minimum. 


Technical specifications :

Measuring rangesAbbemat 300/500 PerformanceAbbemat 350/550 Performance PlusAbbemat Heavy Duty
Refractive index nD
Range [nD]1.26 to 1.721.26 to 1.721.26 to 1.72
Resolution [nD]±0.00001 / ±0.000001±0.00001 / ±0.000001±0.00001 / ±0.000001
Accuracy [nD]±0.0001 / ±0.00002±0.0001 / ±0.00002±0.0001 / ±0.00002
Brix
Range [°Brix]0 to 1000 to 1000 to 100
Resolution [°Brix]±0.01 / ±0.001±0.01 / ±0.001±0.01 / ±0.001
Accuracy [°Brix]±0.05 / ±0.015±0.05 / ±0.015±0.05 / ±0.015
Temperature
Range [°C]4 to 854 to 854 to 125
Temperature probe accuracy [°C]±0.05 / ±0.03±0.05 / ±0.03±0.05 / ±0.03
Temperature probe stability[°C]±0.002±0.002±0.002
Materials / components
Light sourceLED light source, average lifetime 100,000 hours
Wavelength589.3 (by wavelength-adjusted interference filter)
Dimensions [mm]300 x 145 x 330300 x 145 x 330Control unit:
220 x 100 x 295

Measuring unit:
200 x 135 x 200
Weight [kg]6.56.5Control unit: 2.4
Measuring unit: 6.1
Interfaces4 USB, RS232, CAN bus4 USB, RS232, Ethernet, VGA, CAN bus4 USB, RS232, Ethernet, VGA, CAN bus




MCP Sucromat 5300MCP Sucromat 5500
Measuring range±259 °Z (±89.9 °OR)±259 °Z (±89.9 °OR)
Resolution0.001 °OR0.001 °OR
Accuracy±0.003 °OR
±0.01 °Z
<0.002 °OR
<0.006 °Z
Repeatability±0.003 °OR
±0.01 °Z
<0.001 °OR
<0.003 °Z
Response time12 seconds15 seconds
Wavelengths589 nm and optionally 880 nm
Light sourceLED light source, average lifetime 100,000 hours
SensitivityOptical Density (OD) of 4.0, equivalent to OD 7.0 at 880 nm
Temperature control sensorPT100 sensor for sample temperature measurement inside the cell or quartz control plate; wireless transfer to the instrument
Temperature control range20 °C + 25 °C
Dimensions [mm]797 x 437 x 231
Weight [kg]33.5
Interfaces4 USB, RS232, Ethernet, VGA, CAN bus. Easy connection of keyboard, mouse, printer, bar code reader, and networks